Campbell Scientific PWS100 Present Weather Sensor User Manual

Page 44

Advertising
background image

Section 7. Operation

TABLE 7-2. Message Field parameters

Message

Field

Parameter Output

34

External sensor (Aux)

40

Precipitation intensity (mmh

-1

)

41 Precipitation

accumulation

42

Drop size distribution bin values (0.1 mm increment
per value)

43 Average

velocity

(ms

-1

), average size (mm)

44 Type

distribution

45

Size / velocity map type 1 (20

× 20)

46

Size / velocity map type 2 (32

× 32)

47

Campbell Scientific standard size / velocity map (34

× 34)

48

Peak-to-Pedestal ratio distribution histogram

49

Visibility range, in meters, averaged over 10 minutes

100

Internal LED temperatures: upper LED, lower LED

101

Internal detector temperatures: upper, lower

102

Laser hood temperature, laser temperature and laser
current

103

DC offsets: upper, lower, laser

104

Dirty window: upper, lower, laser

105

Battery voltage, hood %, dew %

106

Upper and lower detector differential voltage (mV) and
calibrated visibility voltage (mV)

150

Device s/n, operating system and hardware versions

151

Date and time: day count (from 01/01/2007) HH MM SS

152 Product

name

“PWS100”

153 Statistics

period

(s)

154

Watchdog count, maximum particles per second, particles
not processed, time lag

155 Processing

statistics

156

Year, month, day

157

Hours, minutes, seconds

158

Averaged corrected visibility voltage (mV) and average
upper head voltage (mV)

159 CRC16-CCITT

Checksum

7-8