Appendix I. Phone to RF401 Series

I.2 Non-PakBus Network

Where a phone to RF401 Base

is desired in a non-PakBus network, the

following configurations will provide Point-to-Point or Point-to-Multipoint

communications (using the RF401 Transparent protocol). To have a base

datalogger in this configuration requires that another RF401 be added at the

base.

1. HARDWARE REQUIREMENTS

a. RF401s

b. COM220

c. A100 Null Modem and either the PS100 or CH100

d. AC charger (CSI Item # 9591) or solar panel

e. Two SC12 cables (one included with RF401 and one with COM220)

2. POINT-TO-POINT COMMUNICATIONS (Transparent Protocol)

PC-Modem -- COM220-A100/PS100-RF401 --- RF401-Mixed-array Datalogger

(null-modem)

LoggerNet SETUP
a. Setup:

ComPort_1

PhoneBase

PhoneRemote

RF401

RF401Remote

CR10X

b. ComPort_1 – default settings
c. PhoneBase

1) Maximum Baud Rate – 9600

2). Modem Pick List – per PC’s phone modem

3) Extra Response Time – 0 s

d. PhoneRemote – input base site’s phone number
f. RF401 – make Attention Character: “-“ ; leave the rest defaults
g. RF401Remote – Radio Address: “0” ; leave the rest defaults
g.

CR10X – default settings, schedule collections as desired

RF401 CONFIGURATION
a. Base RF401

1) Active Interface: ME Master

2) Protocol: Transparent

3) CS I/O ME Baud Rate: 9600

b. Remote RF401

1) Active Interface: ME

2) Protocol: Transparent

3) CS I/O Baud Rate: 9600

I-7