Campbell Scientific SR50-L CSC Ultrasonic Distance Sensor User Manual

Page 13

Advertising
background image

SR50 Sonic Ranging Sensor

7

Probe is used and that the SR50 SDI-12/DATA Bus is wired to control port 1
(see Figure 2).

This program is similar to that used on a CR23X.

;{CR10X}
;
*Table 1 Program
01: 60

Execution

Interval

(seconds)


; Measure the 107 temperature probe.
1: Temp (107) (P11)
1: 1

Reps

2: 1

SE

Channel

; S.E. Chan #1 used for this example

3: 1

Excite all reps w/E1

; Excite Chan #1 used for this example

4: 1

Loc [ T_KELVIN ]

5: 1

Mult

6: 273.15 Offset

; This converts the value to degrees Kelvin.


; Measure the SR50 using code ‘1’ for parameter 2. This will cause the SR50 to measure the
distance to target (in meters) and provide a measurement quality number.

2: SDI-12 Recorder (P105)
1: 0

SDI-12

Address

2: 1

Start

Measurement

(aM3!)

; <<< code ‘1’ is used (SEE TABLE 1).

3: 1

Port

; Control Port 1 used for this example.

4: 2

Loc [ DEPTH ]

; Two input locations are used. One for distance and

5: -1

Mult

; one for measurement quality.

6: 0

Offset


; Instruction 105 initiates the measurement using the "0" command in Parameter 2. The single value
; returned to Input Location 2 is the distance to the surface in meters. A multiplier of -1 is used
; because the distance to target value will be subtracted from the distance to ground value to obtain
; snow depth (see 8th instruction).

; The next four instructions apply temperature compensation to the distance value.
3: Z=F x 10^n (P30)
1: 273.15 F
2: 0

n, Exponent of 10

3: 4

Z Loc [ REF_TEMP ]


4: Z=X/Y (P38)
1: 1

X Loc [ T_KELVIN ]

2: 4

Y Loc [ REF_TEMP ]

3: 5

Z Loc [ MULT ]


5: Z=SQRT(X) (P39)
1: 5

X Loc [ MULT ]

2: 5

Z Loc [ MULT ]