1

SR50 Sonic Ranging Sensor

1. SR50 Specifications

Power Requirements:

9-16 VOLTS D.C.


Power Consumption:

2 mA (Quiescent)

250 mA (Measurement Peak)


Measurement Time:

0.6 seconds typical

3.0 seconds max.


Output:

SDI-12 (version 1.2)

Serial

ASCII

- 300 and 1200 Baud TTL or RS-232

- 9600 Baud RS-232 only

Pulse Train (0 to 5 Volts)