4 goesstatus read error register, Goesstatus read error register, 3. goesstatus command 2: read last message status – Campbell Scientific TX320 Transmitter User Manual

Page 33

Advertising
background image

TX320 Transmitter

forward power, reflected power, etc. Also returned is the GPS derived Latitude
and Longitude, which is updated once a day. The GPS update interval can be
changed.

TABLE 7-3. GoesStatus Command 2: Read Last Message Status

Index Contents
1

Command Result Code

2

Message type: Self-timed or Random

3

Size of message in bytes

4

Forward power in tenths of watts

5

Reflected power in tenths of watts

6

Power supply voltage under full load, in tenths of volts

7

GPS acquisition time in tens of seconds

8

Oscillator drift (signed, hundreds of Hz)

9 Latitude

degrees

10 Latitude

minutes

11 Latitude

seconds

12 Longitude

degrees

13 Longitude

minutes

14 Longitude

seconds

7.5.2.4 GoesStatus Read Error Register

Example:

Public Errors(10)

GoesStatus(Errors(), 4)

Command 4 (Read Error Register) is used to return the total number of errors
that have occurred, and codes describing the last four errors. When the
command that caused the error is listed as 31, the error is an internal fault.
Otherwise the error is just a communication error.

TABLE 7-4. GoesStatus Command 4: Read TX320 Error Registers

Index Contents
1 Result

Code

2 Number

of

Errors

3

Command that Caused the Error

4 Error

Code

5

Command that Caused the Error

6 Error

Code

7

Command that Caused the Error

8 Error

Code

9

Command that Caused the Error

10 Error

Code

23

Advertising