I/O Interface Board

CoreModule 800

QuickStart Guide

25

J4
Pin #

Signal

Pin # On-
board

Description

14

RTS1*

J7-16

Request To Send 1 – Indicates serial port is ready to transmit data. Used
as hardware handshake with CTS1 for low level flow control.

15

TXD1
(through
JP1)

J7-12

Transmit Data 1 Output – This line is typically held to a logic 1 when
no data is being sent. A logic 0 (On) must be present on RTS1, CTS1,
DSR1, and DTR1 before transmitting data on this line.

16

CTS1*

J7-17

Clear To Send 1 – Indicates external serial device is ready to receive
data. Used as hardware handshake with RTS1 for low level flow
control.

17

DTR1*

J7-13

Data Terminal Ready 1 – Indicates port is powered, initialized, and
ready. Used as hardware handshake with DSR1 for overall readiness to
communicate.

18

RI1*

J7-18

Ring Indicator 1 – Indicates external serial device is detecting a ring
condition. Used by software to initiate operations to answer and open
the communications channel.

19

GND

J7-14

Digital Ground

20

S1_TXD

JP1-3

Serial Port 2 Transmit TTL – Places TTL TX signals on pin 3 of the
Serial Port 2 (J4) when jumper (JP1) on I/O Board is set to pins 2-3.

21

USBOC0

J4-21

USB 0 Over Current – The Power Distribution Switch (U1) monitors
power and disables port if this input is low.

22

USB Pwr

J4-22

USB Port 0 power (+5V +/-5%)

23

USBP0-

J4-23

Universal Serial Bus Port 0 Data Negative

24

USBP0+

J4-24

Universal Serial Bus Port 0 Data Positive

25

GND

J4-25

USB Ground

26

USBOC1

J4-26

USB 1 Over Current – The Power Distribution Switch (U1) monitors
power and disables port if this input is low.

27

USB Pwr

J4-27

USB Port 0 power (+5V +/-5%)

28

USBP1-

J4-28

Universal Serial Bus Port 1 Data Negative

29

USBP1+

J4-29

Universal Serial Bus Port 1 Data Positive

30

GND

J4-30

USB Ground

31

MSDT

J4-31

Mouse Data

32

MSCK

J4-32

Mouse Clock

33

GND

J4-33

Ground

34

MSPwr

J4-34

Mouse Power (+5V +/-5%)

35

HDDAct

D1-1

IDE Hard Disk Drive Activity – IDE activity signal to HDD Activity
LED (D1).

36

ExtSMI*

J6-2

External SMI – Provides external SMI signal to the CoreModule 800.

37

ThermDP U3-3

Thermal Data Positive – Thermal data positive received from CPU.

38

BatLow*

J6-3

Battery Low –

39

ThermDN U3-4

Thermal Data Negative – Thermal data negative received from CPU.

40

NC

J4-40

Not Connected (External –5V input)