Table B-3 lists the interface between Utility 2a (J5) and the other connectors/devices on the I/O Board.

Table B-3. Utility 2a Interface Pin/Signal Descriptions (J5)

J5
Pin #

Signal

OnBoard
Pin #

Description

1

STB*

NC

J12-1

J11-14

Parallel Strobe* – Output used to strobe data into the printer. I/O pin
in ECP/EPP mode.
Not connected (DS0 – Drive Select 0)

2

AFD*

DEN0

J12-2

J11-2

Parallel Auto Feed – This is a Request signal sent to the printer to
automatically feed one line after each line is printed.
Floppy Drive Density Select Bit 0 – This signal indicates a low
(250/300 kbps) or high (500 kbps) data rate has been selected.

3

PD0

INDEX*

J12-3

J11-8

Parallel Data 0 – These signals (0 to 7) provide the parallel port data
to the printer.
Floppy Index – Sense detects the head is positioned over the
beginning of a track

4

ERR*

HDSel*

J12-4

J11-32

Parallel Error – This is a Status output signal from the printer. A Low
State indicates an error condition on the printer.
Floppy Head Select – Selects FDD side for Read/Write operations
(0 = side 1, 1 = side 0)

5

PD1
TRK0

J12-5

J11-26

Parallel Data 1 – Refer to PD0, pin 3, for more information.
Floppy Track 0 – Sensor detects the head is positioned over track 0.

6

PInit*

DIR*

J12-6

J11-18

Parallel Initialize – This signal used to Initialize printer. Output in
standard mode, I/O in ECP/EPP mode.
Floppy Direction – Direction of floppy head movement
(0 = inward motion, 1 = outward motion).

7

PD2
WrtPrt*

J12-7

J11-28

Parallel Data 2 – Refer to PD0, pin 3, for more information.
Floppy Write Protect – Senses the diskette is write protected.

8

SLIn*

STEP*

J12-8

J11-20

Parallel Select In – This signal used to select the printer. I/O pin in
ECP/EPP mode.
Floppy Step – Low pulse for each track-to-track movement of the head.

9

PD3
RData*

J12-9

J11-30

Parallel Data 3 – Refer to PD0, pin 3, for more information.
Floppy Read Data – Raw serial bit stream from the drive for read
operations.

10

SMB_
Alert

U3-11

J10-3

SMBus Alert – This pin receives signals from thermal monitor (U3).
SMBus Alert – This pin sends/receives to/from external devices.

11

PD4
DskChg*

J12-11
J11-34

Parallel Data 4 – Refer to PD0, pin 3, for more information.
Floppy Disk Change – Senses the drive door is open or the diskette
has been changed since the last drive selection.

12

GND

GND

Ground

13

PD5

J12-13

Parallel Data 5 – Refer to PD0, pin 3, for more information.

14

GND

GND

Ground

15

PD6
NC

J12-15
J11-10

Parallel Data 6 – Refer to PD0, pin 3, for more information.
Not Connected (MTR0 – Motor Control 0)