PROBLEM CHECKING AND METHOD OF PCB

- If you plug in the power cord and turn Power S/W on, memorized data is displayed.

If any data is not displayed, check the followings.

Thermistor Check

Check Voltage at Pin #1 and #2 of CN3

Tester Check = DC 2.7V

If it ready 5V, check if its connector is engaged properly.

Water Sensor Check

Check Voltage and Frequency at Pin #3 and #2 of CN3

Reset water level = DC2.5V, 25.0KHz

Check Voltage and Frequency at Pin #4 and #2 of CN3

Reset water level = DC2.5V, 25.0KHz