Hall Sensor Check (WF364*)

Check Voltage at Pin #4 and #3 of CN8

Tester Check = DC0.6V or 1.3V

Check Voltage at Pin #4 and #2 of CN8

Tester Check = DC0.6V or 1.3V
Motor Check

Resistance at Pin #1 of CN1 and R1-GND = 280# or 470#

Resistance at Pin #2 of CN1 and R1-GND = 280# or 470#

Resistance at Pin #3 of CN1 and R1-GND = 280# or 470#
Door Lock Check

Check Voltage at Pin #1 of CN2 and Pin #6 of CN5

When Door Lock = AC 120V

Drain Motor Check

Check Voltage at Pin #1 of CN2 and Pin #4 of CN5

When Drain Pump operates = AC 120V
Water Valve Check

Check Voltage at Pin #1 of CN2 and Pin #1,2,3 of CN5

When Drain Pump operates = AC 120V
AC Power Check

Check Voltage at Pin #1 and #3 of CN2

Check Voltage at Pin #1 of CN2 and Pin #1 of RY1

Tester Check = AC 120V
Heater Relay Check

Check Voltage at Pin #1 of CN2 and Pin #1 of RY2

When Heater Relay operates = AC 120V