Alignment and adjustments, Warning – Samsung WF361BVBEWR-A2 User Manual

Page 3

Advertising
background image

ALIGNMENT AND ADJUSTMENTS

3

NO

Error Code

(Diagnostic Code

Error Image)

Description

Corrective Action

10

ds

Door is detected as open while it is

trying to lock the door.

Go to “Quick Test Mode” and then do

Door Lock/Unlock Test

11

tE

Abnormal high/low temperature or

resistance (Thermal sensor or PBA

resistance).

Go to “ Board Input Test” and check

Water Temperature. Check loose

or pinched wires. Replace PCB or

thermistor.

12

3E

MICOM is attempting to drive the motor

but is not getting any response signals

from the hall sensor. Visual check shows

motor is not running. (Locked, Defective

Hall Sensor or Overload)(WF364*)

Evaluate wire harness for loose or

unhooked connections. Go to “

Quick Test Mode” and test Motor.

MICOM is attempting to drive the

motor but is not getting any response

signals from the current. Visual check

shows motor is not running. (Locked or

Overload)

13

Hr

Heater Relay Failure (No Heater

Relay Check Signal)

Replace PCB

14

nF1

The hot/cold water hose connection

is not correct.

Please connect the hot/cold water

hose connection correctly.

15

2E

Voltage for motor control bus is over

or under specified limit.

Replace PCB

16

SUd

Suds is detected during the washing

session. (“SUdS” is not an error. If the

washer is in suds period, “SUdS” will

light up instead of remaining time.)

Guide a user to reduce amount of

detergent usage.

17

AE

Communication error between SUB

PBA and MAIN PBA

Check Main PBA, SUB PBA & Wire-

harness. Replace PCB

18

SF

System Error

Replace PCB

To avoid risk of electrical shock, personal injury or death; disconnect power to washer

before servicing, unless testing requires power.

WARNING