_17

6. Review the Electrical Requirements section, then follow the 3 Wire system connection instructions (Step

7) or 4 Wire system instructions (Step 8) below.

7. Three Wire system instructions:

A. External ground connector
b. Neutral grounding wire (green/yellow)
C. Center silver-colored terminal block screw
d. Neutral wire (white or center wire)
e. ¾” (1.9 cm) UL-listed strain relief

1. Loosen or remove the center terminal block screw.
2. Connect the neutral wire (white or center wire) of the power

cord to the center, silver-colored terminal screw of the

terminal block. Tighten screw.

3. Connect the other wires to outer terminal block screws. Tighten screws.
4. Tighten the strain relief screws.
5. Insert the tab of the terminal block cover into your Dryer’s rear panel slot.

Secure the cover with a hold-down screw.

If converting from a 4-wire electrical system to a 3-wire, you must connect the ground strap

to the terminal block support to ground the dryer frame to the neutral conductor.

We recommend using Ring terminals. If you use Strap terminals, please ensure you install

them perfectly.

8. Four Wire System instructions:

A. External ground connector
b. Green or bare copper wire of power cord
C. ¾” (1.9 cm) UL-listed strain relief
d. Center silver-colored terminal block screw
e. Neutral Grounding wire (green/yellow)
F. Neutral wire (white or center wire)

1. Remove the External ground connector screw.
2. Connect the ground wire (green or unwrapped) of the

power cord to the external ground connector screw. If you

want to connect B (Green or bare copper wire of power

cord) to the Neutral Post without connecting it to A (cabinet

ground), call a service technician.

3. Loosen or remove the center terminal block screw.
4. Connect the neutral wire (white or center wire) of the power cord and the appliance ground

wire (green with yellow stripes) under the central screw of the terminal block.

5. Connect the other wires to the outer terminal block screws. Tighten screws.
6. Tighten the strain relief screws.
7. Insert the tab of the terminal block cover into your Dryer’s rear panel slot.

Secure the cover with a hold-down screw.

We recommend using Ring terminals. If you use Strap terminals, please ensure you install