Alignment and adjustments, Error items and diagnostic codes, Warning – Samsung DV361GWBEWR-A3 User Manual

Page 2

Advertising
background image

2

ERROR ITEMS AND DIAGNOSTIC CODES

An occurrence of an Error will make a sound of error melody for 5 sec and continuously show one
of the Error Displays from the following errors.

Error Display

Trigger

Action Taken

tE

The Termistor resistance is very low
or high.

Check for:
- Clogged lint screen.
- Restricted vent system.
- Check Thermistor resistance.

hE

HE

Invalid heating Temp in running the
dryer

Check for:
- Restricted vent system.
- Check Thermistor resistance.

do

dE

Running the dryer with door open

Check for:
- Close the door, and run the dryer
- Loose or open wire terminals in

Door Sense circuit.

dF

Invalid door state for more than
256 milliseconds

Check for:
- Loose or open wire terminals in

Door Sense circuit.

bE

bE2

Invalid state of key circuit short for
30 secs(all models)

Check for:
- Display PCB key circuit short or not

FE

Invalid power source Frequency

Check for:
- Not using regular power source

frequency

- Invalid power frequency sense

circuit

Et

Invalid state of Eeprom
communication

Check for :
- PCB with Eeprom circuit.

ALIGNMENT AND ADJUSTMENTS

WARNING

To avoid risk of electrical shock, personal injury or death; disconnect power to dryer before
servicing, unless testing requires power.

Technical_information-02365J-01_EN.indd 2

2012-09-11 �� 3:09:09

Advertising
This manual is related to the following products: