Specifications — H/AT100R & 120R Models

Data Plate Nomenclature

1 2 3

4

5

6

7

8 9

10

11

12

A T 1

2

0 A

R A E

W

N

A

CURRENT RELEASED REVISION
A - INITIAL RELEASE

BRAND

H =

HeatWave

OPTIONS

AT= AeroTemp

N-NONE

SB = SouthBeach
TZ = Tropez

CABINET COLOR
W - CRÈME
B - BLACK

CAPACITY

REFRIGERANT

100 = 90000 Btus/hr
120 = 109000 Btus/hr

E - R22

155 = 120000 Btus/hr

T - R407C
Z - R410A

CONTROLS

VOLTAGE

A - ANALOG

A - 1/60/208-230

D - DIGITAL

B - 3/60/208 - 230
D - 3/50/380
H - 1/50/200-220

RFRG CONTROL

H - HEAT
R - REVERSING

100-SERIES:

H100AR

AT100AR

H100BR

AT100BR

H100DR

AT100DR

H100HR

AT100HR

BTU - 80%RH

Air

º

F / Air

º

F… 80/50

88,000/63,000

COP

5.6/4.1

BTU - 63% RH

Air

º

F / Air

º

F… 80/50

83,000/57,000

COP

5.3/3.9

Kilowatt Input (80% RH)

4.6

Voltage/Hz/Phase

208-230/60/1 208-230/60/3 380-415/50/3 220-240/50/1

Min. Circuit Ampacity

38.16 22.13 11.62 26.14

Rec. Fuse or Breaker Size

40 30 15 30

Max. Fuse or Breaker Size

60 35 20 40

Min-Max Water Flow (gpm)

20-70 20-70 20-70 20-70

Shipping weight (lbs)

320 320 320 320

Shipping Size (LXW XH)

36” X 40” X 43"

36” X 40” X 43"

36” X 40” X 43"

36” X 40” X 43"

Uncrated Weight

293 293 293 293

120-SERIES:

H120AR

AT120AR

H120BR

AT120BR

H120DR

AT120DR

H120HR

AT120HR

BTU - 80%RH

Air

º

F / Air

º

F… 80/50

103,000/70,000

COP

5.4/4.1

BTU - 63% RH

Air

º

F / Air

º

F… 80/50

99,000/68,000

COP

5/3.8

Kilowatt Input (80% RH)

5.6

Voltage/Hz/Phase

208-230/60/1 208-230/60/3 380-415/50/3 220-240/50/1

Min. Circuit Ampacity

38.16 26.14 12.82 36.56

Rec. Fuse or Breaker Size

40 30 15 40

Max. Fuse or Breaker Size

60 40 20 60

Min-Max Water Flow (gpm)

20-70 20-70 20-70 20-70

Shipping weight (lbs)

330 330 330 330

Shipping Size (LXW XH)

36” X 40” X 43"

36” X 40” X 43"

36” X 40” X 43"

36” X 40” X 43"

Uncrated Weight

303 303 303 303