Winterizing a Heat Pump Equipped with an External Drain

(Continued)

While the plumbing connections are in the winterized condition (not fully tightened), it is imperative pool/
spa water not be circulated through the heat pump. Loss of water through loose plumbing connections
may result in damage to circulating pump, pool-spa structure, and/or other equipment.

Failure to heed the following can result in damage to equipment
and/or property.

CAUTION !

External Winterizing Drain

FIGURE 3