Installation, For qualified installers only), Travis industries – Avalon Stoves Arbor PS User Manual

Page 15

Advertising
background image

Installation

(For Qualified Installers Only)

1 5

© Travis Industries

4070806

1 0 0 - 0 1 1 9 1 _ 0 0 0

Installation Example: Interior Vertical Installation

Floor Protection

24” Minimum

Insulation
must maintain
3” clearance.

Outside air may be drawn from

a ventilated crawl space.

2” Min.

3” Min.

Ceiling Support / Fire Stop Spacer

Roof Flashing

Storm Collar

Vertical Cap

Vent must
maintain 3”
clearance to
combustibles.

“L” Vent

Seal each vent

section (including

adapters, elbows,

etc...) by injecting a

liberal amount of

500° F. RTV

silicone into the gap

between sections.

500

° F. RTV

Silicone

Floor Protection

7” Minimum

6” Minimum

3”

Minimum

2”

Minimum

“Tee”