2 4

Operation

© Travis Industries

4070806

1 0 0 - 0 1 1 9 1 _ 0 0 0

Restrictor Adjustment

The restrictor “fine tunes” your appliance, adjusting the amount of air flowing to the flame.

NOTE

: the optimal restrictor position will vary over time as soot builds up inside the exhaust system.

Not Enough Air

If clinkers (ashes that solidify into
a clump) develop or the flame
appears lazy and slow to blow the
ash out of the firepot, pull the
restrictor outward until the flame
becomes active and the firepot
holes remain clean. NOTE: If the
restrictor is fully out, yet the
firepot does not remain clean,
the stove needs to be cleaned
and checked for air leaks (see
“Maintenance” section of this
manual).

Too Much Air

If the flames are too active (small,
flickering flames) or if burning
pellets are expelled from the
firepot, move the restrictor rod
inwards until the flame slows
down and no burning pellets are
expelled. Another symptom of
too much air is the heater
“blowing the fire out” – a
condition in which the pellets
burn faster than they are fed (this
is most common on low).

Adjusting the Fan Speed

AUTO

OFF

MANUAL

H
E
A
T

F
A
N

UP

DOWN

UP

DOWN

MANUAL

MANUAL

START

AUGER

TRAVIS INDUSTRIES

HOUSE OF FIRE

TM

Press the “up” or “down”

button to adjust the fan

speed.

NOTE: When adjusting

the fan speed the HEAT

OUTPUT lights will flash

the fan speed setting for

one second.

Advertising