Product Errata

11

AMD-8151™ HyperTransport™ AGP3.0 Graphics Tunnel

Revision Guide

25912 Rev. 3.06 March 2006

25 Input Leakage Parameter Out Of Spec

Description

When operating with AGP2.0 signaling, the input leakage current (I

LI

) is specified to be limited to

less than ±10

µA. However, input leakage current may be as much as ±20 µA in some graphics tunnel

parts.

Potential Effect on System

None.

Suggested Workaround

None required.

Fix Planned

No