Product Errata

9

AMD-8151™ HyperTransport™ AGP3.0 Graphics Tunnel

Revision Guide

25912 Rev. 3.06 March 2006

23 Link Electrical Issue When Operating At 800 MHz

Description

The graphics tunnel A-side link may not operate properly at 800 MHz.

Potential Effect on System

Transfer of erroneous data and system deadlocks are possible.

Suggested Workaround

The A-side link should be configured to operate at 600 MHz instead of 800 MHz.

Alternatively, more restrictive system board layout rules for the A-side link may be employed. See the
AMD-8151™ HyperTransport™ AGP3.0 Graphics Tunnel Motherboard Design Guide,
order# 25617 for details.

Fix Planned

No