Page 103 of 468

Device Manager LEDs for AT-8401 Management Module

LED

State

Description

FAN A

Green

Gray

FAN TRAY A is installed and is operating correctly.

FAN TRAY A is not installed.

FAN B

Green

Gray

FAN TRAY B is installed and is operating correctly.

FAN TRAY B is not installed.

MASTER Green

Gray

The switch is the master of an enhanced stack.

The switch is either a slave switch of an enhanced stack or

the switch is not a member of an enhanced stack.

RPS Green

Gray

The switch is receiving power from the redundant power

supply (PWR B).

The switch is receiving power from the main power supply

(PWR A).

PWR Green

Gray (Only if

RPS is installed)

The switch is receiving power from the main power supply

(PWR A).

The main power supply is not functioning.

Note

- Please refer to AT-8400 Line Cards for the operations and behavior of the line cards

installed on the chassis.

Note

- The FAN A and FAN B LEDs are always green regardless of whether or not fan trays

are actually installed.

Note

- The PWR LED is always green and the RPS LED is always gray regardless of whether

the switch is receiving power from the main power supply or the redundant power supply.

Note

- Some parameters, when configured, may at times cause a temporary loss of connection.

When this happens, the following error message appears: "The error occurred with 'Set'

operation. Error: time out occurred.". This will not affect the application in any way.

Agent Menu

From the Agent menu, you can view and edit the system information for the device, or log

into the CLI using Telnet.

System Info

Displays basic system information, including system name, location, contact and

description.