Allied Telesis AT-8088/xx (MT and SC) User Manual

Page 31

Advertising
background image

AT-8000 Series Fast Ethernet Switches Installation Guide

31

The twisted pair ports on the AT-8088/xx switch has two port LEDs,
labeled L/A and D/C. These port LEDs are defined in Table 3 below.

Mode - FULL

OFF

Indicates that the port is operating in half-
duplex mode.

Green

Indicates that the port is operating in full-
duplex mode.

Mode - ACT

OFF

Indicates that there is no activity on the
port.

Flashing
Green

Indicates that the port is transmitting and/
or receiving data packets.

Table 3. AT-8088/xx Twisted Pair Port LEDs

LED

State

Description

L/A

OFF

Indicates that there is no link between the
port and the end-node.

Green

Indicates a valid link has been established
between the port and the end-node.

Flashing
Green

Indicates that the port is transmitting and/
or receiving data packets.

D/C

Green

Indicates that the port is operating in full-
duplex mode.

Amber

Indicates that the port is operating in half-
duplex mode.

Flashing
Amber

Indicates that data collisions are occurring
on the port.

Table 2. AT-8000 Series Twisted Pair Port LEDs

LED

State

Description

Advertising