AT-8000 Series Fast Ethernet Switches Installation Guide

69

Warning

Do not strip more than the recommended amount of wire.
Stripping more than the recommended amount can create a safety
hazard by leaving exposed wire on the terminal block after
installation.

 17

Figure 36. Stripped Wire

4.

Connect the frame ground wire to the terminal marked with the
ground symbol by inserting the wire into the terminal and
tightening the connection with a flathead screwdriver.

Warning

When installing this equipment, always ensure that the frame
ground connection is installed first and disconnected last.

 18

Figure 37. Connecting the Stripped Wire

5.

Connect the positive feed wire to the terminal block marked (+).

6.

Connect the negative feed wire to the terminal block marked (-).

Warning

"Safety Hazard"- Check to see if there are any exposed copper
strands coming from the installed wires. When this installation is
done correctly there should be no exposed copper wire strands
extending from the terminal block. Any exposed wiring can
conduct harmful levels of electricity to persons touching the wires.
 19

8mm ±1mm

(0.31in. ±0.039 in.)

36-60VDC