System leds – Allied Telesis AT-8088/xx (MT and SC) User Manual

Page 34

Advertising
background image

Overview

34

System LEDs

The system LEDs on the front panel display general status information.
They are defined in Table 6.

Table 6. System LEDs

LED

State

Description

Fault

OFF

Indicates normal operation.

Red

Indicates that the switch or management
software has malfunctioned. (Refer to
”Troubleshooting” on page 75 for instructions
on how to troubleshoot the problem.)

Flashing
Red

Indicates that the switch is loading its
operating software, running diagnostic tests,
writing messages to FLASH, or downloading
files using XMODEM.

Master

Amber

Indicates that the switch is functioning as the
master switch of an enhanced stack.

OFF

Indicates that the switch is not a master switch
of an enhanced stack or is not a member of a
stack.

PWR

Green

Indicates that the switch is receiving power.

AT-8016F/xx, AT- 8024M, and AT-8088/xx Switches Only

RPS

Green

Indicates that an optional redundant power
supply is connected to the switch.

OFF

Indicates that there is no optional redundant
power supply connected to the switch.

Advertising