Enter 5 at the prompt for vci value configurati, You must enter a vci value when configuring a pvc, Enter the vci value when prompted – Allied Telesis AT-8202 User Manual

Page 26: Enter 0 to save the selection, Bind the port service for trunking by using the, Use the value of 34 for binding port service to tr

Advertising
background image

Configuring Trunking

1-18

3. Enter

5

at the prompt for VCI value configuration.

Note

You must enter a VCI value when configuring a PVC connection type.
Additionally, make sure the PVC number is identical on all
FORMULA 8200 switches. This must be a different value from the
PTOP.

4. Enter the VCI value when prompted:

5. Enter

0

to save the selection.

6. Bind the port service for trunking by using the

/PORTSERV/

CONFIG/CREATE

command.

Note

Use the value of 34 for binding port service to trunk for ATM.

Enter Selection, 0 to save the Modification or 'q' to Quit:

5

Enter VCI value: 502

TRUNK Configuration

1. TRUNK Index:

1

2. Description (Optional):

TRUNK Instance 1

3. Admin Status(ENABLE(a),DISABLE(b):

ENABLED

4. Connection Type (PVC(a), (SVC(b):

PVC

5. VCI value (Reqd if PVC):

502

6. Destination ATM Address (reqd if SVC):

Enter Selection, 0 to save the Modification or ‘q’ to Quit: 0

New VCI value

Enter Selection, 0 to save the Modification or 'q' to Quit:

0

Updating ATM configuration...