Allied Telesis AT-8324 User Manual

Page 44

Advertising
background image

Installing the Switch

44

As power is applied to the switch, the Fault LED (shown in
Figure 3-2) flashes as the switch runs a series of internal self
tests. After the switch has finished running its self tests, the
Fault LED will stop flashing and will remain OFF.

Figure 3-2 Fault LED

For information on all the switch LEDs, refer to the section
Switch LEDs on page 1-16.

6. If you purchased a redundant power supply (RPS) unit for the

Ethernet switch, connect the RPS unit to the R.P.S. Input
connector on the rear of the switch by following the directions
included with the RPS system.

Caution

If you intend to use a redundant power supply (RPS) with the
switch, check to be sure that the cable with the RPS unit is
compatible with the RPS Input Port on the switch. The pin
assignments for the port are provided in Appendix B.

7. Connect the data cables to the ports on the switch.

8. Go to the procedure Setting Up a Terminal for Local

Management on page 3-59 to access the Omega management
software on the switch.

STATUS

RESET

FAULT

MASTER

RPS

PWR

RS-232

TERMINAL PORT

Fault LED