24

Type of Cabling

For 10 Mbps operation, Category 3 or better 100 ohm shielded or
unshielded twisted pair cabling is required. For 100 Mbps operation,
Category 5 or Enhanced Category 5 (5E) 100 ohm shielded or unshielded
twisted pair cabling is required.

Auto MDI/

MDI-X

The twisted pair ports are auto-MDI/MDI-X. They automatically
configure themselves as either MDI or MDI-X. This feature allows you to
use either straight-through or crossover twisted pair cables to connect
devices to the ports.

Note

Disabling Auto-Negotiation on a port also disables Auto MDI/MDI-X
on the port. You must set the MDI/MDI-X manually through the
management software, refer to the AT-S39 Management
Software User’s Guide
.

Port Pinouts

Refer to

Table 9

on page 84 and

Table 10

on page 84 for the port pinouts.