background image

AT-8000 Series Fast Ethernet Switches Installation Guide

49

Planning the Installation

Table 7 contains the cabling specifications for the twisted pair ports.

Note
The twisted pair ports on the switch feature auto-MDI/MDI-X. They
are configured automatically by the switch as MDI or MDI-X when
connected to an end-node. Consequently, you can use either a
straight-through or crossover twisted pair cable when connecting
any network device to a port on the switch.

Table 7 Twisted Pair Cabling and Distances

Model

Speed

Type of Cable

Maximum
Operating
Distance

AT-8024
AT-8024GB
AT-8024M
AT-8026FC
AT-8026T
AT-8012M
AT-8088/xx

10 Mbps

Category 3 or better
100 ohm shielded or
unshielded twisted
pair cable

100 m (328 ft)

100 Mbps

Category 5 or
Category 5E
(Enhanced) 100 ohm
shielded or
unshielded twisted
pair cable

100 m (328 ft)

AT-8026T

1000 Mbps Category 5 and

Category 5E
(Enhanced) 100 ohm
shielded and
unshielded twisted
pair cable

100 m (328 ft)

Advertising