When purging with “Cleaning-Solution”, always work in three steps.

To clean all 8 heads, first purge the 4 right heads (Lc, Lm, W1, W2), close them,

and in the second stage, purge the remaining 4 left heads (K, C, M, Y).

Finally, open the 4 right heads again, and purge all 8 heads together now.

By doing so, you’ll have the most optimal cleaning pressure.

CLEANING

CLEANING

CLEANING

CLEANING failing heads

failing heads

failing heads

failing heads::::


- Set the valves of the failing heads to the “S” position.

- Set the Solution valve to “S”.

- Push the “Solution-Purge” button on the back of the carriage.

(Keep pushing in a sequence of 2 seconds push and 4 seconds
release until you see a CLEAR “Solution-Curtain”

under the heads, then stop pushing)

- Leave the heads leaking in this condition for at least 5 minutes.

- Set all the valves back to “I”.

- Give a little purge.

- Set the Neg. Pressure to “0”, leave the system for 1 minute
(Ink will now start dripping out the heads)

- Restore the Neg. Pressure back to “-.036”

- Clean the heads with a fiber-free cloth.

- Check on “weeping” (**)