8/08/2008

]

8.4. Long Stand Still

This procedure must be carried out:

- If the engine’s “Stand Still Time” is 1 week or longer…
- If the vacuum pressure is going to be closed down…


SHUTDOWN -- preparing the engine:

- Move the carriage to the Purge position.


- Flush cleaning solution through the heads:

- First flush the 4 right heads (Lc, Lm, W1, W2) and close them,
and in the second stage, flush the remaining 4 left heads (K, C, M, Y).
- Finally, open the 4 right heads again, and flush all 8 heads together now.
By doing so, you’ll have the most optimal cleaning pressure.

- Leave all ink valves in the “S” position, set the Solution valve to “I”.


- On the Engine’s Control Panel, perform a “Head Lift-Up”;

The carriage will go to the highest position.


- Clean the Head Base Plate with a cloth


- Set the Vacuum Pressure to “0”. (Negative Pressure)


- Mount the “Capping Plate” underneath the Head Base Plate.

- use a plastic foil to wrap around the capping plate (new foil every time)

- place a support between the capping plate and the grid.

- bring down the carriage by turning manually, until it’s fixed.

(use some packing material as support)










-

Push the emergency stop, and leave it pushed in! (restart-safety)

- Shut down the engine’s PC.