OM-BLT/BLP-G

WARNING

ELECTRIC POWER ALWAYS SHOULD BE

SHUT OFF BEFORE WORK IS DONE ON

INTERNAL COMPONENTS.

Maintenance

Your braising pan is designed to require minimum maintenance, but certain parts

may need replacement after prolonged use. After installation, no user adjustment

should be necessary. If a service need arises, only authorized personnel should

perform the work.

Service personnel should check the unit at least once a year. This periodic main-

tenance should include inspecting electrical wires and connections, cleaning the

inside of the control console, and possible adjustment of the pilot light. (Units with

standing pilot ignition only) At least twice a year, grease the two trunnion bearings

and worm gear.

We recommend the use of number two grade LGI lithium grease. Add grease through

the zerk fittings on the gear hosing until grease flows out of the bearings around trun-

nion shaft. Also, add grease in the gear to cover arc that is in contact with the worm

gear. Clean up excess grease.

A Service Log is provided with the warranty information at the back of this manual.

Each time service is performed on your equipment, enter the date on which the work

was done, what was done, and who did it. Keep the manual with the equipment for

quick and easy reference.