Troubleshooting – Blodgett BLP-G Series User Manual

Page 17

Advertising
background image

OM-BLT/BLP-G 17

Troubleshooting

Your braising pan will operate smoothly and efficiently if properly maintained. However, the following is a list of checks to make in

the event of a problem. If the actions suggested do not solve the problem, call your qualified Service Representative. If an item on

the list is followed by X, the work should only be performed by a qualified service representative.

A.

ALL MODELS

SYMPTOM

WHO

WHAT TO CHECK

(X indicates work that should only be performed by a qualified service representative)

Pan is hard to tilt.

Authorized

Service Rep Only

a. Gears or foreign materials, lubrication, and alignment. X
b. Broken tilt or worm gears. X

Burners will not light.

User

a. That the main gas supply valve is open (handle is in line with the
gas pipe)
b. Gas supply to the braising pan is at specified pressure.
c. That the pan body is horizontal.

Authorized

Service Rep Only

d. Thermostat operation. The thermostat should click when the dial is
rotated to settings above and below the temperature of the pan. X

Pan continues to heat
after it reaches desired
temperature.

User

a. Thermostat dial setting.

Authorized

Service Rep Only

b. Thermostat calibration. X
c. Thermostat operation. The thermostat should click when the dial is
rotated to settings above and below the temperature of the pan. X

Pan stops heating before
reaching desired
temperature.

User

a. Thermostat dial setting.

Authorized

Service Rep Only

b. Thermostat calibration. X
c. Thermostat operation. The thermostat should click when the dial is
rotated to settings above and below the temperature of the pan. X

Pan heats unevenly.

User

a. That the pan body is horizontal.
b. That the pan is preheated properly in accordance with the
instructions in the Operation section of this manual.

WARNING

BEFORE REPLACING ANY PARTS, DISCONNECT THE UNIT FROM THE ELECTRICAL POWER SUPPLY AND CLOSE THE MAIN GAS VALVE. ALLOW

FIVE MINUTES FOR GAS TO VENT. USE OF ANY REPLACEMENT PARTS OTHER THAN THOSE SUPPLIED BY THE MANUFACTURER OR THEIR

AUTHORIZED DISTRIBUTORS CAN CAUSE INJURY TO THE OPERATOR AND DAMAGE TO THE EQUIPMENT AND WILL VOID ALL WARRANTIES.

SERVICE PERFORMED BY OTHER THAN FACTORY AUTHORIZED PERSONNEL WILL VOID ALL WARRANTIES.