Installation – Blodgett BLP-G Series User Manual

Page 8

Advertising
background image

8

OM-BLT/BLP-G

Install the braising pan in a well ventilated room for efficient performance. Remove

any items which might obstruct or restrict the flow of air for combustion and

ventilation. Clear all combustible material from the area directly around the unit.

1. Installation on combustible floors is allowed. Ensure minimum clearance to

combustible and noncombustible construction.

2. Install the unit under a vent hood.

3. Level the unit by adjusting the bullet feet or floor flanges on the legs. Be sure

the tilting mechanism has been turned all the way to the horizontal position.

Check levelness with a spirit level set on the bottom of the pan body. Anchor the

rear legs securely to the floor if floor flanges are ordered or required.

4. Complete piping to the gas service with 3/4” inch IPS pipe or approved

equivalent.

5. For unit on casters, the installation shall be made with a connector that complies

with the standard for Connectors for Movable Gas Appliances, ANSI Z21.69 - CSA

6.16. Restrain movement of the unit by attaching a cable or chain to the eyelet

provided at the back of the frame and anchor the cable or chain to the wall or

floor. Make the length and location of the cable such that the unit cannot pull on

the gas connection while the cable is connected or quick-disconnect.

6. The gas connection for a unit on casters must be made with a quick-disconnect

device that complies with ANSI Z21.41 - CSA 6.9.

7. For electronic spark ignition, provide 115VAC, 60 HZ, 1 phase, 5 AMP electrical

service to the field wiring control box at the rear of the electrical console. AN

ELECTRICAL GROUND IS REQUIRED. The unit must be electrically ground in

accordance with local codes, or in the absence of local codes, with the National

Electrical Code, ANSI/NFPA 70, or the Canadian Electrical Code, CSA C22.2, as

applicable.

8. Installation must conform with local codes or with the American National

Standard Z223, latest edition, National Fuel Gas Code. The pan should be

installed in an adequately ventilated room with a provision for adequate air

supply to the unit. The best ventilation will use a vent hood and exhaust fan. DO

NOT obstruct the flue or vent duct after installation. In Canada, installation must

conform to CAN/CGA B149 Installation Codes for Gas Appliances and Equipment

and/or local codes.

WARNING

INSTALLATION OF THE BRAISING PAN

MUST BE DONE BY PERSONNEL QUALIFIED

TO WORK WITH GAS AND ELECTRICITY.

IMPROPER INSTALLATION CAN RESULT IN
INJURY TO PERSONNEL AND/OR DAMAGE

TO EQUIPMENT.

Installation

CAUTION

INSTALLER MUST VERIFY THAT THE

INSTALLATION COMPLIES WITH THE

APPLICABLE LOCAL CODES AND

REGULATIONS. THE UNIT MUST BE

INSTALLED BY A LICENSED PLUMBER OR

GAS FITTER WHEN INSTALLED WITHIN THE

COMMONWEALTH OF MASSACHUSETTS.

WARNING

THIS UNIT IS FOR COMMERCIAL USE.

NEVER USE HOME OR RESIDENTIAL GRADE

GAS CONNECTIONS. THEY DO NOT MEET

GAS CODES AND COULD BE HAZARDOUS.

WARNING

ELECTRICALLY GROUND THE UNIT AT

THE TERMINAL PROVIDED. FAILURE

TO GROUND UNIT COULD RESULT IN

ELECTROCUTION AND DEATH.

Minimum

Clearance

Recommended Clearance

Left Side

0”

2” for service
6” when faucet is installed on left side

Right Side

0”

12-16” for service
6” when faucet is installed on right side

Rear

3”

12” for service

Electronic spark ignition