Cleaning – Blodgett BLP-E Series User Manual

Page 15

Advertising
background image

OM-BLT/BLP-GE 13

Cleaning

11. Following supplier instructions, apply the sanitizing agent after the unit has

been cleaned and drained. Thoroughly drain off the sanitizer.

12. After the unit has been cleaned, sanitized and drained, let all surfaces air

dry unless the unit must be used again right away.

13. It is recommended that the unit be sanitized just before use. Follow the

directions of the sanitizer supplier.

14. About once a week (more often if the water is very hard), use a heavy

duty cleaner to remove any mineral deposits or film left by hard water or

foods. Follow the supplier’s directions very carefully, and rinse the unit off

thoroughly, as soon as cleaning is finished.

15. If especially difficult cleaning problems persist, contact your cleaning

product supplier for help. The supplier has a trained technical staff with

laboratory facilities to serve you.

CAUTION

NEVER LEAVE A CHLORINE SANITIZER IN

CONTACT WITH STAINLESS STEEL

SURFACES FOR LONGER THAN 30 MINUTES.
LONGER CONTACT CAN CAUSE CORROSION.

CAUTION

KEEP CAUSTIC COMPOUNDS SUCH AS

FRYER BOILOUT CLEANERS AWAY FROM

ALUMINUM PARTS OF THE LID HINGE

SYSTEM AND THE COUNTERBALANCE

ASSEMBLY. HIGHLY CAUSTIC COMPOUNDS

COULD DAMAGE THIS MATERIAL.