Internal wiring for the Braising Pan is supplied complete. When you receive the unit, it

is ready for connection. A wiring diagram is located inside the control box on the right

side of the pan, as well as in this manual.

Your pan was performance-tested at the factory to confirm that all controls and

heating elements were functioning correctly.

Installation is as follows:

1. Set the unit in place and level it by turning the adjustable feet. Crank the pan

body to a completely horizontal position. Check levelness by placing a spirit level

on the bottom of the pan. The unit must be level to avoid uneven cooking across

the pan.

2. Make a waterproof connection with the incoming power line at the electrical

service entrance at the bottom of the connection box at rear of control console.

A BX connection is NOT recommended. ELECTRICALLY GROUND THE UNIT at the

proper terminal.

3. Provide the proper electrical supply as specified on the electrical information

plate. Comply with local codes and the National Electrical Code ANSI/NFPA 7-

latest edition.

4. Use only copper wire, rated at least 75ºC and of proper gage. See chart below.

5. Standard equipment is shipped ready for 208V, 240V, or 480V, 3-phase

operation. Refer to the wiring diagram located on the inside cover of the control

box and the instructions below for conversion to single-phase operation.

A jumper wire and “conversion” label are included with the unit. They can be

found in a plastic bag attached to the trunnion assembly inside the control box.

WARNING

INSTALLATION OF THE BRAISING PAN

MUST BE DONE BY PERSONNEL QUALIFIED

TO WORK WITH ELECTRICITY. IMPROPER

INSTALLATION CAN RESULT IN INJURY TO

PERSONNEL AND/OR DAMAGE

TO EQUIPMENT.

Installation

CAUTION

BEFORE ANY ELECTRICAL CONVERSION,

VERIFY THAT THE BRANCH CIRCUIT

WIRING IS ADEQUATE TO HANDLE ANY

INCREASE IN AMPERAGE REQUIREMENTS.

REFER TO THE ELECTRICAL

SPECIFICATIONS LISTED BELOW.

Model

Power

208 Volt,

Single Phase

240 Volt,

Single Phase

208 Volt,

3-Phase

240 Volt,

3-Phase

400 Volt,

3-Phase, 4 Wire

480 Volt,

3-Phase

Kw

Amps

Wire

(AWG)

Amps

Wire

(AWG)

Amps

Wire

(AWG)

Amps

Wire

(AWG)

Amps

Wire

(AWG)

Amps

Wire

(AWG)

30E-BLT

11.5

56

6

48

6

32

8

28

10

17

14

14

14

30E-BLP

11.5

56

6

48

6

32

8

28

10

17

14

14

14

40E-BLT

15.3

74

4

64

4

43

8

37

8

22.5

12

19

14

40E-BLP

15.3

74

4

64

4

43

8

37

8

22.5

12

19

14

Electronic spark ignition

Electrical Requirements
Note: Use only copper wire rated for 75°c or higher

Advertising