Blodgett BLG-G User Manual

Page 9

Advertising
background image

9

3.0 OPERATION INSTRUCTIONS (Continued)


START-UP PROCEDURE



1. Open manual gas shutoff valve.

2. Ensure that the braising pan is in the DOWN position.

3. Turn THERMOSTAT dial to desired setting. The red TEMPERATURE LIGHT will

come on. This will turn on the electronic ignition which will light the burners.


4. If the green IGNITION LIGHT does not come on after 30 seconds, turn

THERMOSTAT OFF and then ON again for restart.


5. When braising pan has reached set temperature, the red TEMPERATURE LIGHT

will go off and the burners will shut off. The burners will cycle on and off thereafter to
maintain set temperature. The red TEMPERATURE LIGHT will be on when the
burners are on and off when burners are off.


6. If gas supply is interrupted during operation, turn THERMOSTAT dial to OFF position

and turn gas supply OFF. Wait 5 minutes, then repeat Steps 1 through 4 to restart.


7. Turn THERMOSTAT to OFF when braising pan is not in use.


DAILY SHUTDOWN PROCEDURE


Turn THERMOSTAT dial to OFF. Close manual gas shutoff valve.