14

OM-KLT-E

Maintenance

CAUTION

KEEP GREASE AWAY FROM ELECTRICAL

PARTS LOCATED NEAR THE GEARS.

WARNING

TO AVOID INJURY, READ AND FOLLOW ALL

PRECAUTIONS STATED ON THE LABEL OF

THE WATER TREATMENT COMPOUND.

WARNING

ELECTRIC POWER ALWAYS SHOULD BE

SHUT OFF BEFORE WORK IS DONE ON

INTERNAL COMPONENTS.

CAUTION

BEFORE YOU HEAT THE KETTLE AGAIN
FOR ANY PURPOSE, TURN THE ELBOW

BACK CLOCKWISE UNTIL THE OPENING

FACES DOWNWARD.

WARNING

DISCONNECT ELECTRICAL POWER FROM

THE UNIT BEFORE ATTEMPTING TO GREASE

THE TRUNNION BEARINGS.

CAUTION

NEVER LEAVE A CHLORINE SANITIZER

IN CONTACT WITH STAINLESS STEEL

SURFACES FOR LONGER THAN 30
MINUTES. LONGER CONTACT CAN

CAUSE CORROSION.

d.

Air introduced to the jacket during filling must be removed to obtain

efficient heating. See “Jacket Vacuum.”

8.

Water Treatment Procedure

a.

Obtain water treatment compound and a pH test kit from your

authorized parts distributor.

b.

Fill a mixing container with the measured amount of water required.

(See table). Distilled water is recommended.

c.

Hang a strip of pH test paper on the rim of the container, with about

1 inch of the strip below the surface of the water.

d.

Measure the water treatment compound. One way to do this is to add

the compound from a measuring cup.

e.

Stir the water continuously, while you slowly add treatment compound,

until the water has a pH between 10.5 and 11.5. Judge the pH by

frequently comparing the test strip color with the color chart provided in

the test kit. If you are color blind use an electroanalytical instrument to

measure the pH level or have a person who is not color blind read the

test strip color level.

f.

As you add water to the jacket, check water level to ensure that it

is between minimum and maximum marks on gauge. Stop adding water

when it reaches the maximum marker on the gauge.


g.

Record the exact amounts of water and treatment compound needed.

These amounts may be used again, if the same water sources and

compound are used. However, it is best to check the pH each time

treated water is prepared.

9.

Component Replacement Service Personnel should check the unit at least

once a year. This periodic maintenance should include inspecting electrical

wires and connections, and cleaning the inside of the control console.

At least twice a year, grease the two trunnion bearings and worm gear. We

recommends the use of number two grade LGI lithium grease. Add grease

through the zerk fittings on the gear hosing until the grease flows out of the

bearings around the trunnion shaft. Also, add grease in the gear to cover arc

that is in contact with the worm gear. Clean up excess grease.

Kettle Model

Jacket Capacity

20E-KLT

3-1/4 Gallons

(12.3 liters)

40E-KLT

4-1/2 Gallons

(17.0 liters)

60E-KLT

5 Gallons

(18.9 liters)

Advertising