2. Specifications

Model

2.5-10Ч40

2.5-10Ч50

3.5-14Ч40 SF

3.5-14×50 SF

4.5-18×40 SF

3.5-14×50 SF IL

4.5-18×40 SF IL

Actual Magnification

2.5-10Ч

2.5-10Ч

3.5-14Ч

3.5-14Ч

4.5-18Ч

3.5-14Ч

4.5-18Ч

Objective Diameter

(mm)

40

50

40

50

40

50

40

Exit Pupil*

(mm)

4

5

2.9

3.6

2.2

3.6

2.2

Eye Relief**

(mm)

(in)

97-97

4.0-4.0

97-97

4.0-4.0

97-97

4.0-4.0

97-97

4.0-4.0

97-97

4.0-4.0

97-97

4.0-4.0

97-97

4.0-4.0

Tube Diameter

(mm)

(in)

25.4

1

25.4

1

25.4

1

25.4

1

25.4

1

25.4

1

25.4

1

Objective Tube Diameter

(mm)

(in)

50.3
1.98

60.3
2.37

50.3
1.98

60.3
2.37

50.3
1.98

60.3
2.37

50.3
1.98

Outside Diameter of Eyepiece

(mm)

(in)

44

1.73

44

1.73

44

1.73

44

1.73

44

1.73

44

1.73

44

1.73

Adjustment Graduation

1 click: 7 mm @ 100 m

1 click: 1/4 in @ 100 yd

1 click: 7 mm @ 100 m

1 click: 1/4 in @ 100 yd

1 click: 7 mm @ 100 m

1 click: 1/4 in @ 100 yd

1 click: 7 mm @ 100 m

1 click: 1/4 in @ 100 yd

1 click: 3.5 mm @ 100 m

1 click: 1/8 in @ 100 yd

1 click: 7 mm @ 100 m

1 click: 1/4 in @ 100 yd

1 click: 3.5 mm @ 100 m

1 click: 1/8 in @ 100 yd

Max Internal Adjustment
(Elevation & Windage)

***(MOA)

70

70

55

55

40

55

40

Parallax Setting

(m)

(yd)

91.44

100

91.44

100

45.72-∞

50-∞

45.72-∞

50-∞

45.72-∞

50-∞

45.72-∞

50-∞

45.72-∞

50-∞

Power Source

3-Volts Lithium CR2032

3-Volts Lithium CR2032

Reticle Intensity Adjustment

6 position (OFF to 5) for Green color and Red color

6 position (OFF to 5) for Green color and Red color

Field of View at 100 m/yd**

(m)

(ft)

13.5-3.3
40.4-9.9

13.5-3.3
40.4-9.9

9.5-2.4

28.6-7.2

9.5-2.4

28.6-7.2

7.5-1.9

22.4-5.6

14.8-4.3
28.6-7.2

14.8-4.3
22.4-5.6

Length

(mm)

(in)

319

12.6

347

13.7

345

13.6

364

14.3

345

13.6

364

14.3

345

13.6

Weight

(g)

(oz)

435

15.3

510

18.0

490

17.3

550

19.4

485

17.1

565

19.9

500

17.6

EMC

EU:EMC directive, AS/NZS

EU:EMC directive, AS/NZS

Environment

RoHS, WEEE

RoHS, WEEE

*at maximum magnification **(at minimum magnification)-(at maximum magnification) ***MOA = Minute of Angle

3. Instructions

(1) Replacement of the battery and adjusting the illumination

CAUTION: When installing batteries, make sure the firearm is unloaded. Use safe firearm handling
practices at all time.

The PROSTAFF 5 Riflescope 3.5-14×50 SF IL and 4.5-18×40 SF IL are powered by one 3V lithium battery (CR2032). When your reticle
grows dim or not light at all, you need to replace the battery.

How to replace battery
1 Hold the rheostat intensity dial tightly and turn the cover with battery cover opener 1 counter-clockwise (Fig. 3-1).

2 Take out the old battery and put one 3V Lithium Battery 2 into the compartment. Be sure (+) side to be up (Fig. 3-2).

3 Put the cover back and turn it clockwise with battery cover opener until the cover in firmly secured.