Operating instructions, Overnight burning – Aarrow Fires EcoBurn BK043 User Manual

Page 26

Advertising
background image

26

Aarrow Ecoburn Wood & Multifuel Stoves

OPERATING INSTRUCTIONS

ENSURE THAT YOU HAVE READ &
UNDERSTOOD THESE INSTRUCTIONS
BEFORE LIGHTING THE FIRE.

ALWAYS WEAR SUITABLE PROTECTIVE
FIRE GLOVES WHEN REFUELLING YOUR
STOVE.

SOLID FUEL

BURNING

(Multifuel

Version Only)

•Set the grate to ‘coal’ position.
•Ensure that the ash pan is in position and the fire

doors are closed.

•Set the air wash (secondary air) to one quarter

open position.

•Set the primary inlet to the fully open position
•Light in the normal manner with paper and

kindling, or use a fire lighters.

•If using a gas poker be sure to remove it

immediately when the fire is alight.

•When the fire is well alight regulate the burning

rate by adjusting the setting on the primary air
inlet control.

•The air wash can be opened sufficiently to keep

the door glass clean.

BURNING WOOD

•When burning wood on multifuel version set to
grate to wood burning position.
•If wood burning only version no further settings
are required.
•Set the air wash to fully open position.
•Proceed as for solid fuel but note the fire will burn
up and become established more quickly.
• Ensure primary air control is in the fully closed
position. Note some familiarisation may be
required due to fuel variation and some adjustment
may be necessary.

MIXED FUELS (Multifuel Version Only)

•The grate can be set to either coal or wood

position depending on the main percentage of
the fuel to be burnt.

•As per coal but allow additional secondary air.
•The primary air inlet can be closed and burning

regulated by means of the air wash above the door.

ANTHRACITE (Multifuel Version Only)

Anthracite is more difficult to keep in for long

periods, consequently more care in setting the
controls and some familiarisation is necessary
when burning anthracite.
Use the smallest size fuel (Stovesse or Small Nuts).
Proceed as for manufactured smokeless fuel. Leave
the air inlet control open about a quarter or less.

Note: The high temperature paint acquires
durability by being "cured" during the initial
firings of the appliance. During this time, fumes
which are non-toxic, are emmitted, certain persons
may find they have an unpleasant or irritant effect.
Ensure that the area is well ventilated during this
time.

OVERNIGHT BURNING

The appliance will burn overnight provided:
•Sufficient fuel is placed in the firebox.
•The controls are set correctly.
•Excess draught is not present in the chimney.
•Close the door.
•If the fire goes out with unburnt fuel left in the

firebox increase the air opening slightly, and vice

versa.

In the morning
Open the air control fully until embers begin to
glow brightly and place pieces of fuel on the fire
until it is well established.

WARNING: When wood is burnt slowly in a
closed appliance it produces moisture and tar,
which will create condensation and deposits in the
chimney. This effect can be minimised by burning
hard for a short period, about 20 minutes, twice a day.
It is usually convenient to do this morning and night.
Note: To avoid chimney problems your fire should
not be burnt slowly for longer than 12 hours
without a period of fast burning.

WARNING: Properly installed, with a suitable
flue and chimney and operated and maintained
this appliance will not emit fumes into the
dwelling. Occasional fumes from the de-ashing
and re-fuelling may occur. However, persistent
fume emission is potentially dangerous and must
be investigated by a Hetas registered installer.
Stop using the appliance if you smell fumes or
see smoke escaping.