ROTHENBERGER ROMAX 3000 User Manual

Page 22

Advertising
background image

ENGLISH

16

3.7

Operation

E

Use only system-compatible press fittings and press jaws designed for them. The nominal size of

the press jaw must be identical with the nominal size of the press fitting.

When inserting the pipe / press fitting system, there is a risk of crush injuries for the fingers

or other body parts near the press jaw!

Press lightly the ON button to light up, white LED’s lights up for 30 sec.

Push the press fitting on to the pipe (1). Pull the press jaw apart and insert the pipe with the
press fitting at right angles.

There must be no foreign bodies between the press contour and the fitting. If you fail to

ensure this, the pressing process will not produce a perfect joint!

Press the ON button until the pressing process has been completed (2). The motor cut out

indicates the end of the moulding cycle.

Push the press jaw apart and take the machine off the joint (3).

Do not start the machine while the piston retracts or the emergency shutdown is pressed!

3.8

Battery/Charger

F

Mains connection:
Connect only to single-phase a.c. current and only to the system voltage indicated on the rating

plate. It is also possible to connect to sockets without an earthing contact as the design conforms

to safety class II.
Charging the battery:

ATTENTION! Overvoltage destroys the batteries and the charger. Observe correct

mains voltage.

The lithium-ion battery can be charged at every charging level and charging can be interrupted at

any time without damaging the battery (no memory effect).

Insert mains plug of the battery charger into a mains power socket:

Red and green LEDs are lit.

Connect the battery (1) to the battery charger (2):
Charging control lamp (3) flashes green: Battery is charged.
Charging control lamp (3) is lit green: Battery is fully charged. (For charging time, see

Technical Data).

Keep button pressed and remove the battery.

Disconnect mains power plug from the mains power socket.

Storage:
The place of storage must be inaccessible for children.

Keep button pressed and remove the battery.

Disconnect mains power plug from the mains power socket.

Store battery charger in a dry, frost-proof place.

Store the battery only in a charged state! Fully recharge the battery after 12 months of

storage, at the latest!
Troubleshooting:
Before eliminating faults, disconnect the mains power plug!

- Fault lamp (4) is lit red: Battery temperature outside the permissible charging temperature

(5°C to 45°C).

- Fault lamp (4) flashes red: Battery is defective.

If the battery temperature is between 5°C and 45°C and the red fault lamp (4) is nevertheless lit,

there may be a faulty contact.

- Clean contact points on battery.

In the event of other faults, please contact Rothenberger Service. Repairs should only be carried

out by ROTHENBERGER service centres or dealers authorised by ROTHENBERGER.