ROTHENBERGER ROWELD D 4/15 Aero Basic User Manual

Page 28

Advertising
background image

26

ENGLISH

5.5

Set temperatures on temperature controller

Temperature chart:

Material Melttemperature Airtemperature

PP

200 – 240 °C

250 – 300 °C

PE

200 – 240 °C

250 – 300 °C

PVDF

240 – 260 °C

280 – 350° C

If other temperatures are needed, the corresponding settings can be made on the temperature
controller.
Set/operate temperature controller (1) - Function/description of LEDs

LED

GREEN

LED

RED

Operating mode

FLASHES

OFF

Heating element is being checked.

FLASHES

FLASHES

Temperature setting on temperature controller (1) is below the
minimum temperature, controller position approx. 20 (2). The
drive is blocked – cold start protection.

ON

FLASHES

Temperature setting on temperature controller (1) is above the
minimum temperature. On the minimum temperature being
reached, a timer is activated. Preheat time: 10 minutes.

ON

OFF

Ready for operation: timer has timed out,
drive has been released for operation.

OFF

FLASHES

Air failure: Allow machine to cool, pull mains connector, plug in
mains connector and heat up to just above the minimum tem-
perature, i.e. approx. position 30 (3).
On a renewed air failure, check the heating element and re-
place, if necessary.

OFF

ON

Current draw too high.
RESET by pressing the controller switch.
Check air temperature; if necessary, select a higher tempera-
ture and / or speed on the drive.

Guide values for air temperature / melt temperature

Check temperatures on the running extruder with an external thermometer after about 5
minutes.

Advertising