ROTHENBERGER ROWELD D 4/15 Aero Basic User Manual

Page 30

Advertising
background image

28

ENGLISH

Malfunction

Fault No.

Extruder does not heat up

2, 3, 22

Temperature above preset range

2, 3, 18, 19

Controller fluctuates

3, 13,19

Fault No.

Possible causes

Remedies

1

Smaller or too small a welding rod
diameter

Use larger welding rod diameter, if
necessary

2

Temperature sensor defective

1)

3

Temperature controller defective

1)

5

Cable connections defective

Check cable connections.

1)

8

Hot air temperature below start inter-
lock temperature

Allow hand extruder to heat up

9

Melt temperature below start interlock
temperature

Allow hand extruder to heat up

10

Preheat time for hot air too short

Allow hand extruder to heat up

11

Preheat time for melt too short

Allow hand extruder to heat up

13

Air supply not constant

1)

14

Wrong rated voltage

Rated voltage > permissible voltage
Check mains voltage
Rated voltage < permissible voltage
Check mains voltage

1)

15

Extension cable heats up

Unroll cable reel
Check cable cross-section (see also
section “Safety“)

16

Extruder nozzle plugged with foreign
matter

Clean extruder.

Extruder nozzle – left-hand thread

17

Drive unit defective

1)

18

Electronic control defective

1)

19

Controller programming error

1)

20

Welding rod feed

Remove welding rod

Observe instructions in section
“Maintenance“!
Observe instructions for operation!

22

Hot air unit defective

1)

23

No mains voltage

Check voltage supply

1)

Consult ROTHENBERGER Werkzeuge GmbH

Advertising