trOubleshOOtInG (continued)

Control Board LEDs

The Control Board has three onboard LEDs (Figure

5) to determine the status of the unit and to assist in

troubleshooting.

green (Diagnostic): The LED should be off in normal

operation. However, if any of the 5 potential faults are

detected by the Control Board, this LED will repeatedly

blink either 1 through 5 times with a 2 second pause in

between (refer to the Green LED Blink Codes section

below).

yellow (Audio): When lit, this LED indicates that the

Control Board is supplying approximately 10-15 VDC to

the audio signal. The audio signal should sound when

this LED is lit.

Red (heat): When lit, this LED indicates that the

Control Board is calling for heat by supplying VDC to

terminals 3(+) and 4(-) of the Solid State Relay. When

off, it means that the grill platen is up to operating

temperature and satisfied.

green LED Blink Codes

Control Board

LED Activity

unit state

Condition

The Green LED

blinks on and off

1 time, pauses for

2 seconds, and

repeats.

The EEPROM memory on the Control

Board is corrupted.

In this state, the unit turns off the control signal to the Solid

State Relay and disables all front buttons and lights. The unit

will not heat up. This continues until the defaults are reloaded

into memory. To reload the defaults, turn the unit off, press and

hold the

tIme 2 button, turn the unit back on, and release the

button.

The Green LED

blinks on and off

2 times, pauses

for 2 seconds, and

repeats.

The ambient temperature within the

control compartment has exceeded

155ºF (68ºC). Verify that there is proper

air ventilation around the unit and that it

is not near a significant heat source.

In this state, the unit turns off the control signal to the Solid

State Relay and disables all front buttons and lights. The unit

will not heat up. This continues until the ambient temperature

within the electrical compartment drops below 140ºF (60ºC)

and the unit is turned off and back on.

The Green LED

blinks on and off

3 times, pauses

for 2 seconds, and

repeats.

Open or disconnected Thermocouple.

In this state, the unit turns off the control signal to the Solid

State Relay and disables all front buttons and lights. The unit

will not heat up. This continues until the Thermocouple is

reconnected or replaced, and the unit is turned off and back

on.

The Green LED

blinks on and off

4 times, pauses

for 2 seconds, and

repeats.

The supply voltage to the unit is below

160 VAC or above 265 VAC.

In this state, the unit turns off the control signal to the Solid

State Relay and disables all front buttons and front lights. The

unit will not heat up. This continues until the supply voltage is

within the proper limits and the unit is turned off and back on.

The Green LED

blinks on and off

4 times, pauses

for 2 seconds, and

repeats.

The 50/60 Hz signal has been lost due

to a loose, disconnected, or an open

wire harness/wiring on the AC Isolator

Board, or from the AC Isolator Board to

the Control Board.

In this state, the unit turns off the control signal to the Solid

State Relay and disables all front buttons and lights. The unit

will not heat up. This continues until the 50/60 Hz signal is

reapplied and the unit is turned off and back on.

NOTE: During heat mode, this Red LED is very dim,

so it may be difficult to verify if the Control Board

is calling for heat. It is recommended that you

observe the small round green LED on the Solid

State Relay (Figure 6) for mode and diagnostic

purposes. When the green LED on the Solid State

Relay is on, it means that the Control Board is call-

ing for heat. when off, it means that the control

Board is NOT calling for heat. Typically, the VDC at

the Solid State Relay will be less than 1.0 VDC when

measured, but may vary because of different quality

VOMs. Therefore, it is recommended that you do

NOT attempt to measure the VDC at the Solid State

Relay for diagnostic purposes.

HEAT

BUZZ

STATUS

CR4

CR3

CR5

YELLOW

GREEN

RED

R17

R20

R18

Figure 5. Control Board

LEDs

Figure 6. Solid State

relay

R

PRODUCT SERVICE

TUV

.

gapruit

Bauart

Crouzet

GN

84137220

4/A2-

3-32 VDC

+3/A1

1/L1

2/T1

50 AMP 24-280 VAC

Solid State

Relay

LED

Advertising
This manual is related to the following products: