egg station

12

P/N 1011004 Rev. B 08/08

TRoUblesHooTInG (continued)

control board leDs

The Control Board has three on board LEDs (Figure 8)

to determine the status of the unit and to assist in

troubleshooting.
Green (Diagnostic): This LED should be off in nor-

mal operation. However, if any of the 5 potential faults

are detected by the Control Board, this LED will blink

repeatedly either 1 through 5 times with a 2 second

pause in between. See the green LeD Blink Codes

section below.
yellow (audio): When lit, this LED indicates that the

Control Board is supplying approximately 10-15 VDC to

the audio signal. The audio signal should sound when

this LED is lit.
Red (Heat): When lit, this LED indicates that the

Control Board is calling for heat by supplying VDC to

the Solid State relay terminals 3(+) and 4(-). When off,

this means that the Grill Surface is up to operating

temperature and satisfied.

Green leD blink codes

number of

blinks

cause(s)

Unit’s state and Resolution

The Green LED

blinks on and off

1 time, pauses for

2 seconds, and

repeats.

Control Board’s EEPRoM memory is

corrupted.

In this state, the unit turns off the control signal to the Solid

State Relay and disables all front buttons and front lights.

The unit will not heat up. This continues until the defaults are

reloaded into the memory. To reload the defaults, turn the unit

off, press and hold the Time 2 button, turn the unit back on,

and then release the button.

The Green LED

blinks on and off

2 times, pauses

for 2 seconds, and

repeats.

The ambient temperature within the con-

trol compartment has exceeded 68ºC

(155ºF). Verify that the unit has proper

air ventilation all around it and that it is

not near a significant heat source.

In this state, the unit turns off the control signal to the Solid

State relay and disables all front buttons and front lights. The

unit will not heat up. This continues until the ambient tem-

perature within the electrical compartment drops below 60ºC

(140ºF) and the unit is turn off and turned on again.

The Green LED

blinks on and off

3 times, pauses

for 2 seconds, and

repeats.

open or disconnected Thermocouple.

In this state, the unit turns off the control signal to the Solid

State Relay and disables all front buttons and front lights. The

unit will not heat up. This continues until the Thermocouple is

reconnected or replaced and the unit is turned off and turned

on again.

The Green LED

blinks on and off

4 times, pauses

for 2 seconds, and

repeats.

Supply voltage to the unit is below 160

VAC or above 265 VAC.

In this state, the unit turns off the control signal to the Solid

State Relay and disables all front buttons and front lights. The

unit will not heat up. This continues until the supply voltage is

within the proper limits and the unit is turned off and turned on

again.

The Green LED

blinks on and off

5 times, pauses

for 2 seconds, and

repeats.

The 50/60 Hz signal has been lost due

to a loose, disconnected, or open wire

harness/wiring on the AC Isolator Board,

or from the AC Isolator Board to the

Control Board.

In this state, the unit turns off the control signal to the Solid

State Relay and disables all front buttons and front lights. The

unit will not heat up. This continues until the 50/60 Hz signal is

reapplied and the unit is turned off and turned on again.

noTe: During heat mode, this Red leD is very dim,

so it may be difficult to verify if the control board

is or is not calling for heat. It is recommended

that you observe the small round green leD on the

solid state Relay (figure 9) for mode and diagnos-

tic purposes. When the green leD on the solid

state Relay is on, it means that the control board is

calling for heat. When off, it means that the control

board is noT calling for heat.

figure 8. control board

leDs

figure 9. solid state

Relay

R

PRODUCT SERVICE

TUV

.

gapruit

Bauart

Crouzet

GN

84137220

4/A2-

3-32 VDC

+3/A1

1/L1

2/T1

50 AMP 24-280 VAC

Solid State

Relay

LED

HEAT

BUZZ

STATUS

CR4

CR3

CR5

YELLOW

GREEN

RED

R17

R20

R18

Advertising