3.1 Symbol Explanation
Use and Safety Precautions are marked by symbols and they start with the appropriate signal word
to express their importance.
Please follow the given instructions and warnings to avoid risk of health and damage of property

I

WARNING!

… Indicates a possible dangerous situation which may cause risk of health

I

CAUTION!

… Indicates a possible dangerous situation which may cause damage of property

Recommendations

NOTE!

… Additional information for an efficient and optimal operation

3.2 Information about this Installation and Operation Manual
This installation and operation manual provides the necessary information for the correct installation
and operation of the filter system.
Please make sure that the installation complies with applicable state and local regulations for the
operation, installation and for the disposal of used filters as well.
Each person handling and operating the filter system has to read and understand the installation and
operation manual completely.

3.3 Limited Warranty and Liability
The Manufacturer warrants, to the original purchaser/consumer, all equipment that it manufacture’s
to be free from defects in materials and workmanship for a period of 2 years from the date of
purchase. This warranty is subject to exclusions and limitations.

2.2 Operation Conditions

VIZION HRS

100

200

Inlet/Outlet fittings

3/8” BSP male

Nominal flow rate

US gallons/d (L/d)

US/gallons/min (L/min)

720 (2.725)

0.5 (1.9)

Working pressure, min-max

psi (bar)

29 – 116 (2 – 8)

Required water pressure inlet

psi (bar)

>17.4 (>1.2)

Pressure drop at 8 US gallons/h (0.5 Litres/min)

(1)

psi

(bar)

1.5

(0.10)

2.9

(0.20)

Pressure drop at 16 US gallons/h (1 Litres/min)

(1)

psi

(bar)

2.2

(0.15)

4.4

(0.30)

Pressure drop at 48 US gallons/h (3 Litres/min)

(1)

psi

(bar)

7.3

(0.50)

8.7

(0.60)

Water temperature, min-max.

°F (°C)

+39 to +86 (+4 to +30)

Ambient temperature, min-max.

°F (°C)

+39 to +100 (+4 to +38)

Transportation and storage ambient temperature,

min-max

°F (°C)

-4 to +100 (-20 to +38)

Operation/Installation position

horizontal or vertical

(1)

Blend setting „2“, including a 59.06 (59 1/16) inch (1.5 m) hose DN8 mounted on inlet and outlet