UF SERIES watER FIltRatIon SyStEm

11

P/N 1010827 Rev. E 03/12

A.J. Antunes & Co.

figure 4. proper Draining

2” (5.1 cm)

minimum

2” (5.1 cm)

minimum

floor

Drain

secure

end

Drain line

from system

Drain line

from system

secure

end

Drain

standpipe

InstallatIOn (continued)

OperatIOn

figure 5. leD Display, front panel

START

starting the system

Power up the unit.

The LED read-out displays the following for about two

seconds each:

1. 8.8
2. Fd followed by its time settings in seconds.
3. Fi and its time setting, in minutes or hours.

The

Fd and Fi sequence repeats for 30 seconds

after which, the unit automatically returns to the

Flush Interval Mode (Fi). The time setting for Fi

will be displayed and the decimal point will flash in

one second intervals.

nOte: the timer can be programmed immediately

after start-up or while in flush Interval mode.

filtration process

Water filtration in the UF Series is accomplished using

two modes:

• Flush Interval (Fi on the LED display)

• Flush Duration (Fd on LED display).

During the Flush Interval mode, water enters the inlet

and flows through the filter element before exiting the

Permeate outlet as usable product water. After a cer-

tain period of time, depending upon water quality, the

filter has to be cleaned. This is accomplished through

the Flush Duration Mode. During this mode, the drain

valve opens and flushes the membrane to remove

debris collected inside the membrane walls.

nOte: both the flush Interval mode and the flush

Duration mode can be automated by programming

the timer. During the flush Interval mode, the valve

is not powered in order to keep water filtering during

a power outage.

leD Display

Fi - Flush Interval Mode is the time between flushings

and is displayed in minutes or hours.

Fd - Flush Duration Mode is the amount of time used

to flush and remove debris from filter cartridge and

is displayed in seconds.

FL - Manual Flush Mode operation, solenoid is