Uf series water filtration system, Specifications, A.j. antunes & co – A.J. Antunes & Co UF-440 9700453 User Manual

Page 6: Electrical ratings, Filter cartridge capacities, System capacities

Advertising
background image

UF SERIES watER FIltRatIon SyStEm

6

P/N 1010827 Rev. E 03/12

A.J. Antunes & Co.

specIfIcatIOns

electrical ratings

caUtIOn

all electrical connections must be in accordance

with local electrical codes and any other

applicable codes.

warnInG

electrIcal sHOcK HaZarD.

faIlUre tO fOllOw tHe InstrUctIOns In

tHIs manUal cOUlD resUlt In serIOUs InJU-

rY Or DeatH.

• Electrical ground is required on this appliance.
• Do not modify the power supply cord plug. If

it does not fit the outlet, have a proper outlet

installed by a qualified electrician.

• Do not use an extension cord with this

appliance.

• Check with a qualified electrician if you are in

doubt as to whether the appliance is properly

grounded.

model

Voltage

watts

Hertz

UF-420

120

10

50/60

UF-440

230

10

50/60

electrical cord & plug configurations

letter

code*

Description

configuration

C

H

Commercial Cord

Harmonized Cord

(H)C**

CEE 7/7, 16 Amp.,

250 VAC (Assembly

only).

(C)F***

5-15P, 15 Amp., 120

VAC., Non – Locking

(Assembly only).

(h)K

Chinese/Australian,

10 Amp., 250 VAC.

(Assembly only)

WHT BLK

GRN

* Used in model Designation

** Indicates that the Plug comes with a Harmonized Cord

** Indicates that the Plug comes with a Commercial Cord

filter cartridge capacities

Maximum operating Pressure

100 psig (690 kPa)

Maximum operating Temp.

104°F (40°C)

Minimum operating Temp.

40° F ( 4° C)

Maximum Membrane Differential Pressure

45 psi

pH Range

3-10

MWCo

100 kD

system capacities

series

Uf-420

Uf-440

Liters per hour

1500

2000

Liters per minute

25

33.3

Gallons per hour

396

528

Gallons per minute

6.6

8.8