UF SERIES watER FIltRatIon SyStEm

5

P/N 1010827 Rev. E 03/12

A.J. Antunes & Co.

Inlet water

pressure

(psi)

Inlet turbidity

(ntU)

required additional equipment

Installed

water Use

(Gallons per

Day)

flush program

Less than 45 psi

Less than 1 NTU Required: No additional equipment

Recommended: Inlet water strainer

(150 micron/ 100 mesh screen)

Recommended: Permeate Tank

Less than

300 GPD

Greater than

300 GPD

Flush Program:

Interval: 6 hour

Duration: 15 seconds

Flush Program:

Interval: 1 hour

Duration: 15 seconds

Greater than

45 psi

Less than 1 NTU Required: Pressure regulator

Recommended: Inlet water strainer

(150 micron/ 100 mesh screen)

Recommended: Permeate Tank

Less than

300 GPD

Greater than

300 GPD

Flush Program:

Interval: 6 hour

Duration: 15 seconds

Flush Program:

Interval: 1 hour

Duration: 15 seconds

Less than 45 psi

Greater than

1 NTU

Required: Inlet water strainer (150

micron/ 100 mesh screen)

Required: Permeate Tank

Any

Flush Program:

Interval: 1 hour

Duration: 15 seconds

Greater than

45 psi

Greater than

1 NTU

Required: Pressure regulator

Required: Inlet water strainer (150

micron/ 100 mesh screen)

Required: Permeate Tank

Any

Flush Program:

Interval: 1 hour

Duration: 15 seconds

The following table describes the required or recommended equipment and suggested flush programming to be used

with your filtration system based on the Inlet Water Pressure, Inlet Turbidity, and daily water use.

water cOnDItIOn eqUIpment GUIDelInes

Advertising