Vzn v series, Installation (continued) – A.J. Antunes & Co VZN-441V-T5 9700751 User Manual

Page 10

Advertising
background image

VZN V SERIES

10

P/N 1011079 Rev. I 12/13

CAUTION

Due to its weight and size, the VZN system MUST be

mounted with the provided Mounting Bracket. Read

the Mounting the System section before attempting to

mount the VZN system. Use care when lifting heavy

objects.

Mounting the System

NOTE: Use caution when lifting and mounting the sys-

tem. The system MUST be mounted using the provided

Mounting Bracket.

The VZN system comes with a Mounting Bracket. When

mounting the system, pay attention to the following guidelines:

• Allow sufficient access for cartridge replacement. The

VZN-441V and VZN-441V-T5 should be mounted with 40

inches to the top or bottom.

• Mount the system near but NOT above an appropriate

electrical outlet.

• Mount the system near a drain for flushing operations.
• Mount the system before all consumable water

filtration processes.

• Mount the system with the provided Mounting Bracket

and hardware capable of supporting 120 lbs. or more.

• Secure the Mounting Bracket into wall studs or with the

appropriate heavy duty mounting hardware.

The system is pre-assembled to a Back Plate. The Back Plate

has mounting holes across the bottom portion to secure the

bottom of the system to the wall. Some of the bottom mount-

ing holes may be obscured. Plan your mounting accordingly.

Follow these steps to secure the Mounting Bracket to the wall

and seat the VZN system:

1. Use a stud finder and level to attach the Mounting

Bracket securely to the wall with the appropriate

mounting hardware (Figure 2).

2. The Mounting Bracket is designed so that the VZN

system can be lifted and hung on the Mounting Bracket.

With assistance, lift the system and seat it onto the

Mounting Bracket securely (Figure 2).

INSTALLATION (continued)

3. Secure the bottom portion of the VZN system to the

wall using the holes provided. Make sure the mounting

hardware secures the system into wall studs or use the

appropriate mounting hardware.

4. Screw the Carbon Element Housing onto the Carbon

Element Head without the Carbon Element installed.

NOTE: Do NOT install the Carbon Element at this time.

The Carbon Element should only be installed after the

Ultra Filter Cartridge has been rinsed.
5. On VZN-441V-T5 units, screw the TAC Housing onto

the TAC Head without the TAC Cartridge installed.

NOTE: Do NOT install the TAC Cartridge at this time. The

TAC Cartridge should only be installed after the Ultra

Filter Cartridge has been rinsed.

Secure Mounting Bracket

to wall studs using

appropriate hardware.

The system is

designed to hang from

the Mounting Bracket.

Back Plate

(holes along bottom

for additional

mounting stability)

Figure 2. Mounting the System

Advertising
This manual is related to the following products: