MAINTENANCE (continued)

Rinsing and Replacing the TAC Cartridge

(VZN-441V-T5 ONLY)

System Sanitization

The system and downstream plumbing should be sanitized

every six months. When necessary, follow the procedure in

Sanitizing the System and Lines in the Installation section

of this manual.

O-ring

TAC

Housing

TAC

Cartridge

TAC

Head

Red Pressure

Relief Button

Gasket

TAC

Housing

TAC

Cartridge

Figure 10. Removing the TAC Housing (VZN-441V-T5 only)

Figure 11. Replacing the TAC Cartridge (VZN-441V-T5 only)

bon Element installed.

1. Turn off water to the system by closing the Inlet

Ball Valve and then close the Outlet Ball Valve.

2. Press the

FLUSH button to initiate the flush cycle.

Repeat several times to ensure the permeate tank

is empty.

3. Press and hold the Red Pressure Relief Button on

the top of the TAC Housing (Figure 4) to lower the

water level inside the housing by 2 to 3 inches.

4. Remove the TAC Housing (Figure 3).

5. Empty any water into a drain and discard the old

TAC Cartridge (Figure 4).

6. Inspect the O-ring on the TAC Housing. Replace

the O-ring if it is cracked, twisted, or missing.

7. Lubricate the O-ring with an approved food grade

lubricant and install into the TAC Housing.

8. Install the new TAC Cartridge into the TAC Hous-

ing with the arrow on the cartridge pointing up.

NOTE: Make sure the End Seal gaskets are in place in

the recessed grooves on both ends of the TAC

Cartridge (Figure 4).

9. Screw the TAC Housing (containing the TAC Car-

tridge) into place on the TAC Head. The Housing

will come to a hard stop at the end of the thread.

Use a Filter Wrench if necessary.

10. Direct water from the Rinse Ball Valve to drain.

NOTE: It is important to direct the Rinse Ball Valve to

a drain as the water resulting from the flush

should NOT be used.

11. Turn on the water to the system by slowly open-

ing the Inlet Ball Valve and allow water to flow

through the TAC Cartridge and Housing to clear

out trapped air and any carbon fines that may be

present.

12. To help remove trapped air from the TAC Housing,

press the Red Pressure Relief button on the top of

the Housing until water just begins to come out.

13. Rinse the TAC Cartridge for at least 5 minutes.

NOTE: Do NOT consume the water used for rinsing the

TAC Cartridge.

14. When the TAC Cartridge rinsing is complete, close

the Rinse Ball Valve and open the Outlet Ball

Valve.

15. Reconnect the water to service. The system is

now ready for use.