Vzn v series, Installation (continued) – A.J. Antunes & Co VZN-441V-T5 9700751 User Manual

Page 14

Advertising
background image

VZN V SERIES

14

P/N 1011079 Rev. I 12/13

INSTALLATION (continued)

Rinsing the Carbon Element and TAC Cartridge

The Carbon Element and TAC Cartridge MUST be rinsed

before using the system the first time and immediately after

the Carbon Element or TAC Cartridge have been replaced.

NOTE: If Installed, remove the TAC Cartridge Element

before proceeding. Do not rinse a new Carbon Element

with the TAC Cartridge Element installed.

1. Install the Carbon Element into the Carbon Element

Housing.

2. Screw the Carbon Element Housing (containing the

Carbon Element) into place on the Carbon Element

Head. The Housing will come to a hard stop at the end

of the thread. Use a Filter Wrench if necessary.

3. If installed, remove the TAC Cartridge Element from the

TAC Cartridge Housing.

4. Screw the empty TAC Housing into place on the TAC

Head. The Housing comes to a hard stop at the end of

the thread. Use a Filter Wrench if necessary.

5. Direct water from the Rinse Ball Valve to a drain. Then

open the Rinse Ball Valve and close the Outlet Ball

Valve.

6. Turn on the water to the system by slowly opening the

Inlet Ball Valve.

7. Allow water to flow through the Carbon Element and

TAC Housings to flush out trapped air and any debris

that may be present.

8. To help remove trapped air from the Housings, press

the RED Pressure Relief Button on the top of the hous-

ings until water just begins to come out.

9. Flush the Carbon Element for at least 5 minutes.

10. Install the TAC Cartridge Element into the TAC Housing

with the arrow on the cartridge pointing up. Reattach

the TAC Housing to the system. Flush for at least 5

minutes.

NOTE: Do NOT consume water used during this process.

11. Close the Rinse Ball Valve when rinsing completes.

12. Open the Outlet Ball Valve. The system is now ready

for use.

13.

For new piping installations: After making the

connection to the System Outlet:

Open the faucet or tap closest to the filter system

Slowly open the Inlet Valve.

Allow the pipe to flush until all debris is removed.

Sanitizing the System and Lines

The plumbing must be sanitized to eliminate possible contam-

ination that may have occurred during the installation process.
One ounce (30 ml) of liquid chlorine bleach (regular bleach,

unscented 5.25 % - 6 % sodium hypochlorite) or Kay-5

sanitizer solution (Sodium Dichloro-s-Triazinetrione Dihydrate,

6%) or equivalent can be used to sanitize the plumbing.
The Kay-5 sanitizer solution is made by dissolving a 1 oz.

packet of Kay-5 powder in 2 oz. (60 ml) of clean warm water.

This can be done by removing 1 inch from the top of the

Kay-5 packet and adding the 2 oz. of warm water to the pack-

et. Mix with a coffee stirrer to dissolve. When added to the

system, this will create a 60-100 ppm chlorine solution.
NOTE: Follow the handling and safety instructions

supplied with the sanitizer.
NOTE: If installed, remove the Carbon Element and TAC

Cartridge from the system BEFORE Sanitizing.

1. Follow the steps in the

Rinsing the Ultra Filter

Cartridge in the Installation section of this manual.

2. Turn off the water to the system.

3. Open the faucet or tap closest downstream to the

system.

4. Allow the system and plumbing to drain.

5. Remove the plug installed in the sanitizing "T" fitting at

the inlet of the system. Allow the water to drain out of

the system.

6. Pour the sanitizer into the inlet sanitation fitting using a

cup or funnel. Be careful not to spill the sanitizer onto

clothing or skin.

7. Reattach the plug on the sanitation fitting.

8. Slowly turn on the water supply to the system.

9. Allow water to flow through the system and out of the

open faucet or tap until the smell of sanitizer is present.

10. Close the faucet or tap.

11. Let the system stand without water flow for at least 15

minutes to allow the sanitizer to sanitize the pipes.

12. After 15 minutes without water flow, open the faucet or

tap.

13. Allow water to flow through the system until the

presence of sanitizer is gone.

14. Open all other faucets and taps in line with the system

to flush any remaining sanitizer from the plumbing.

15. Close all faucets and taps.

Advertising
This manual is related to the following products: