Troubleshooting – Karcher SDP 9500 User Manual

Page 19

Advertising
background image

– 11

Troubleshooting

ƽ

Danger

To avoid risks, all repairs and replacement of spare parts may only be carried out by au-
thorized customer service personnel.
First pull out the plug from the mains before carrying out any tasks on the machine.

Fault

Cause

Remedy

Pump runs but does
not transport

Air in the pump

Press the ventilation button or plug in/
disconnect the mains plug of the pump
a few times till the fluid gets sucked.

Suction area blocked

Pull out the mains plug and clean the
suction area

(only in manual mode) Wa-
ter level below the minimum
water level

Immerse, whenever possible, the pump
deeper into the liquid or, in case of SCP
9000, proceed according to instructions
in the chapter on flat suction.

Max. flow height exceeded Adjust the max. flow height as de-

scribed in Chapter Prepare / Fig. G.

Pump does not run
or suddenly comes
to a standstill during
operations

Power supply interrupted

Check fuses and electrical connections

Motor protection fuse
switched off the motor be-
cause of overheating

Pull out the mains plug, let the pump
cool down, clean the suction area, pre-
vent dry running

Dirt particles have got
jammed into the suction
area

Pull out the mains plug and clean the
suction area

Pump operation stopped by
sensor

Check position of level sensor

Pumping capacity is
reducing

Suction area blocked

Pull out the mains plug and clean the
suction area

Pumping capacity
too low

The pumping capacity de-
pends on the flow height,
hose diameter and hose
length.

Keep max. flow height, see technical
data. If necessary, select a different
hose diameter or hose length.

Our Kärcher branch will be pleased to help you further in the case of questions or faults.